Manor Lakes Building
Inspections

The small slab nobody looks at

Hot water service pads, and the membrane and isolation strip they need.

Manor Lakes 3024 · 5 January 2026

In short: It is a square of concrete beside the house. It still has an engineering detail, and on one Manor Lakes slab it had been skipped.

What we recorded

On a slab inspection in August 2025, the hot water service pad had no damp proof membrane and no isolation strip, both called for by the engineering.

Why the membrane matters

Without it, ground moisture rises into the pad and the base of the unit and its fittings sit in damp concrete.

Why the strip matters

The isolation strip lets the pad and main slab move separately. Without it, movement can crack one or the other at the junction.

When it is fixable

Before the pour, in minutes. After, it means breaking out concrete next to a fitted appliance.

The bigger lesson

Small slabs and set-downs are easy for everyone to treat as an afterthought. They are on the engineering for a reason.

Written by our local inspection team from work carried out in Manor Lakes. Licensed building practitioners, Building & Plumbing Commission registration CDB-U 53425.

Guides

More new construction stage inspections guides for Manor Lakes

All guides →

Book a building inspection in Manor Lakes

Instant online pricing, or talk to the booking team on 1300 471 805.

FAQ

Questions Manor Lakes owners ask about this

Is this a structural defect?

It is a departure from the engineering. The consequences are usually damp and cracking rather than structural failure.

Do you check other small slabs?

Yes: porches, alfresco slabs and set-downs where they are poured with the main slab.

What else did that slab show?

Mesh touching pipes, missing trimmer bars and a missing shower recess bar.

Is it too late after the pour?

The membrane cannot be added. The builder would need to propose a fix.