A July 2026 Manor Lakes waterproofing inspection found membrane applied directly to particleboard flooring in a first floor wet area. Why that matters.

  • Manor Lakes 3024
  • 24 September 2026
  • 3 min read
Price your inspectionLeave your details and a Manor Lakes inspector calls you back.

No obligation. We use your details for your quote and may contact you about it even if you don't finish.

Fully licensed & accredited

In short: Membrane is only as good as what it is stuck to. In an upstairs wet area in Manor Lakes, it was stuck to particleboard.

What we found

On a July 2026 waterproofing inspection, the first floor wet area had membrane applied directly over particleboard flooring. The same visit recorded damaged membrane and walls with thick lumps of membrane that would have pushed tiles out of plane.

Why the substrate matters

The Housing Provisions list materials suitable as water resistant substrates in wet areas. Particleboard swells if it ever gets wet, and a floor that moves will crack grout and eventually the membrane above it.

Why upstairs raises the stakes

A failed ground floor shower wets a slab. A failed upstairs shower wets a ceiling, a living room and sometimes electrical fittings below. Many Manor Lakes homes now have their main ensuite upstairs.

What to ask for

Before tiling, ask the builder to confirm the substrate is a compliant wet area material or provide the approved alternative. Once tiles are down, the only check left is running the shower at handover and watching the ceiling below.

Written by our local inspection team from work carried out in Manor Lakes. Licensed building practitioners, Building & Plumbing Commission registration CDB-U 53425.

Blog

More from the Manor Lakes blog

All posts →

Book a building inspection in Manor Lakes

Instant online pricing, or talk to the booking team on 1300 471 805.

FAQ

Questions Manor Lakes owners ask about this

Can this be fixed after tiling?

Only by removing the tiles and membrane. That is why the inspection sits before the tiler.

Is waterproofing inspected at handover too?

Indirectly. We run every shower and look for leaks, but the membrane itself is hidden by then.